Options:
TTL on/off Heatsink
Features:
Over Voltage Protection Thermal Monitor Forward Power Detection
|
| Min | Typ | Max | Unit |
Operating Temperature | 0 | | 55 | °C |
Operating Humidity | | 95% | | |
Operating Altitude | | 10000 | | Ft |
RF Input Connector | SMA F |
RF Output Connector | SMA F |
|
| Min | Typ | Max | Unit |
RF Frequency | 2300 | | 2700 | MHz |
P1dB Power Output | 43.5 | 44 | | dBm |
Linear Gain | | 55 ±1 | | dB |
Gain Flatness Over Band | | ±1 | | dB |
Gain Change Over Temp | | ±1 | | dB |
Third Order Intercept (OIP3) | | 63 | | dBm |
Operating Characteristics
| Min | Typ | Max | Unit |
Supply Voltage | | 12 | | VDC |
Operating Current Draw | | 8.5 | | A |
Pin | Value | Description |
RF Input |
- 9 dBm, typical |
Input Connector (SMA Female) |
RF OUTPUT |
+ 44 dBm @ P1dB |
Output Connector (SMA Female) |
RF SAMPLE |
30 dBr |
Sample RF Port ( SMA Female ) |
GND |
--- |
Ground Turret |
FWD |
+ 33 dBm Output Power ? + 2.0 Volts |
Forward Power Detector |
REV |
? VSWR @ + 37 dBm ? + 2.0 Volts |
Reverse Power Detector |
+12VDC |
+ 12 Volts @ 8.5 Amperes (typ.) |
DC Input Voltage |
On/Off |
0 Volts = Off, +5 Volts = On |
TTL Logic On/Off |
CNTL |
Switching Speed up to 100 kHz |
TTL Pulse Control |
|
|